{"id":35041,"date":"2025-08-27T13:39:28","date_gmt":"2025-08-27T13:39:28","guid":{"rendered":"https:\/\/oakbridgecollege.co.uk\/?post_type=lp_course&#038;p=35041"},"modified":"2026-07-31T08:01:44","modified_gmt":"2026-07-31T08:01:44","slug":"systemes-electriques-et-centrales-de-production-conception-installation-et-maintenance","status":"publish","type":"lp_course","link":"https:\/\/oakbridgecollege.co.uk\/fr\/courses\/systemes-electriques-et-centrales-de-production-conception-installation-et-maintenance\/","title":{"rendered":"Syst\u00e8mes \u00c9lectriques et Centrales de Production (Conception, Installation et Maintenance)"},"content":{"rendered":"<h2 data-section-id=\"9oxh8g\" data-start=\"26\" data-end=\"77\">Syst\u00e8mes \u00c9lectriques et Centrales de Production<\/h2>\n<h2 data-section-id=\"1c3a0ab\" data-start=\"78\" data-end=\"121\">(Conception, Installation et Maintenance)<\/h2>\n<p><strong>Programme : Syst\u00e8mes Modernes d\u2019\u00c9nergie \u00c9lectrique \u2013 Conception, Exploitation et Contr\u00f4le<\/strong><\/p>\n<hr data-start=\"217\" data-end=\"220\" \/>\n<h3 data-section-id=\"1gb0ixd\" data-start=\"222\" data-end=\"249\">Pr\u00e9sentation du Programme<\/h3>\n<p data-start=\"251\" data-end=\"347\">L\u2019industrie de l\u2019\u00e9nergie \u00e9lectrique conna\u00eet aujourd\u2019hui une transformation rapide sous l\u2019effet :<\/p>\n<ul data-start=\"349\" data-end=\"487\">\n<li data-section-id=\"obotwf\" data-start=\"349\" data-end=\"374\">de la d\u00e9r\u00e9glementation,<\/li>\n<li data-section-id=\"yfubjs\" data-start=\"375\" data-end=\"403\">de l\u2019innovation num\u00e9rique,<\/li>\n<li data-section-id=\"r5y6ym\" data-start=\"404\" data-end=\"438\">des exigences environnementales,<\/li>\n<li data-section-id=\"e5yise\" data-start=\"439\" data-end=\"487\">et d\u2019une complexit\u00e9 op\u00e9rationnelle croissante.<\/li>\n<\/ul>\n<p data-start=\"489\" data-end=\"564\">Cette formation intensive de 5 jours offre une vue d\u2019ensemble compl\u00e8te de :<\/p>\n<ul data-start=\"566\" data-end=\"661\">\n<li data-section-id=\"yqcqcq\" data-start=\"566\" data-end=\"582\">la production,<\/li>\n<li data-section-id=\"18fdiku\" data-start=\"583\" data-end=\"598\">le transport,<\/li>\n<li data-section-id=\"1vhct9v\" data-start=\"599\" data-end=\"617\">la distribution,<\/li>\n<li data-section-id=\"123b741\" data-start=\"618\" data-end=\"661\">et l\u2019utilisation de l\u2019\u00e9nergie \u00e9lectrique,<\/li>\n<\/ul>\n<p data-start=\"663\" data-end=\"779\">ainsi que des techniques modernes d\u2019analyse, de planification, de contr\u00f4le et de protection des r\u00e9seaux \u00e9lectriques.<\/p>\n<p data-start=\"781\" data-end=\"885\">Con\u00e7u pour les ing\u00e9nieurs, techniciens et professionnels du secteur de l\u2019\u00e9nergie, ce programme combine :<\/p>\n<ul data-start=\"887\" data-end=\"1004\">\n<li data-section-id=\"17usfw1\" data-start=\"887\" data-end=\"917\">les fondamentaux th\u00e9oriques,<\/li>\n<li data-section-id=\"krznly\" data-start=\"918\" data-end=\"959\">les applications industrielles r\u00e9elles,<\/li>\n<li data-section-id=\"1mtclqw\" data-start=\"960\" data-end=\"1004\">et les tendances technologiques actuelles.<\/li>\n<\/ul>\n<p data-start=\"1006\" data-end=\"1216\">Les participants d\u00e9velopperont une compr\u00e9hension approfondie des composants essentiels des syst\u00e8mes \u00e9lectriques modernes ainsi que des d\u00e9fis \u00e9conomiques, techniques et environnementaux qui fa\u00e7onnent le secteur.<\/p>\n<p data-start=\"1218\" data-end=\"1273\">Le programme adopte une approche syst\u00e9mique int\u00e9grant :<\/p>\n<ul data-start=\"1275\" data-end=\"1413\">\n<li data-section-id=\"i0xlk9\" data-start=\"1275\" data-end=\"1301\">l\u2019ing\u00e9nierie \u00e9lectrique,<\/li>\n<li data-section-id=\"12kkhwv\" data-start=\"1302\" data-end=\"1329\">la stabilit\u00e9 des r\u00e9seaux,<\/li>\n<li data-section-id=\"1me2k3e\" data-start=\"1330\" data-end=\"1346\">la simulation,<\/li>\n<li data-section-id=\"vj8a5m\" data-start=\"1347\" data-end=\"1363\">la protection,<\/li>\n<li data-section-id=\"7x1bup\" data-start=\"1364\" data-end=\"1380\">le monitoring,<\/li>\n<li data-section-id=\"rz5i08\" data-start=\"1381\" data-end=\"1413\">et l\u2019optimisation \u00e9nerg\u00e9tique.<\/li>\n<\/ul>\n<hr data-start=\"1415\" data-end=\"1418\" \/>\n<h3 data-section-id=\"1vxwg2w\" data-start=\"1420\" data-end=\"1447\">Objectifs de la Formation<\/h3>\n<p data-start=\"1449\" data-end=\"1516\">\u00c0 l\u2019issue de cette formation, les participants seront capables de :<\/p>\n<ul data-start=\"1518\" data-end=\"2781\">\n<li data-section-id=\"pq8xt2\" data-start=\"1518\" data-end=\"1599\">Comprendre l\u2019architecture et les composants des syst\u00e8mes \u00e9lectriques modernes<\/li>\n<li data-section-id=\"ie66mn\" data-start=\"1600\" data-end=\"1699\">Expliquer les principes de production \u00e9lectrique :\n<ul data-start=\"1655\" data-end=\"1699\">\n<li data-section-id=\"1ym41ii\" data-start=\"1655\" data-end=\"1667\">thermique,<\/li>\n<li data-section-id=\"p12bvh\" data-start=\"1670\" data-end=\"1682\">synchrone,<\/li>\n<li data-section-id=\"190ckiq\" data-start=\"1685\" data-end=\"1699\">distribu\u00e9e<\/li>\n<\/ul>\n<\/li>\n<li data-section-id=\"13ox30u\" data-start=\"1700\" data-end=\"1785\">Analyser les transformateurs et leurs applications dans la conception des r\u00e9seaux<\/li>\n<li data-section-id=\"uf6w0h\" data-start=\"1786\" data-end=\"1896\">Comprendre les structures des lignes de transport \u00e9lectrique ainsi que les calculs de fl\u00e8che et de tension<\/li>\n<li data-section-id=\"1rjm7rx\" data-start=\"1897\" data-end=\"2006\">Identifier les diff\u00e9rents types de postes \u00e9lectriques et les syst\u00e8mes de mise \u00e0 la terre et de protection<\/li>\n<li data-section-id=\"1m7aw5\" data-start=\"2007\" data-end=\"2071\">Mod\u00e9liser et analyser les r\u00e9seaux de distribution \u00e9lectrique<\/li>\n<li data-section-id=\"o4czud\" data-start=\"2072\" data-end=\"2140\">Comprendre les techniques modernes d\u2019exploitation et de contr\u00f4le<\/li>\n<li data-section-id=\"1ewc0so\" data-start=\"2141\" data-end=\"2234\">D\u00e9crire les syst\u00e8mes de comptage, la mod\u00e9lisation des charges et la gestion de la demande<\/li>\n<li data-section-id=\"12xi0nu\" data-start=\"2235\" data-end=\"2294\">R\u00e9aliser des analyses de d\u00e9fauts et simulations syst\u00e8me<\/li>\n<li data-section-id=\"1nt6867\" data-start=\"2295\" data-end=\"2368\">Comprendre les syst\u00e8mes de protection \u00e9lectrique et relais num\u00e9riques<\/li>\n<li data-section-id=\"1igrwpl\" data-start=\"2369\" data-end=\"2434\">\u00c9valuer la stabilit\u00e9 et la dynamique des syst\u00e8mes \u00e9lectriques<\/li>\n<li data-section-id=\"1v05n11\" data-start=\"2435\" data-end=\"2519\">Comprendre les m\u00e9thodes de planification et indicateurs de fiabilit\u00e9 des r\u00e9seaux<\/li>\n<li data-section-id=\"1tomr3u\" data-start=\"2520\" data-end=\"2609\">\u00c9tudier les applications de l\u2019\u00e9lectronique de puissance et de la qualit\u00e9 de l\u2019\u00e9nergie<\/li>\n<li data-section-id=\"xoz3me\" data-start=\"2610\" data-end=\"2692\">Appliquer des m\u00e9thodes d\u2019optimisation \u00e9conomique pour les centrales thermiques<\/li>\n<li data-section-id=\"1nl4gzn\" data-start=\"2693\" data-end=\"2781\">Identifier les enjeux li\u00e9s \u00e0 la s\u00e9curit\u00e9 des syst\u00e8mes et au contr\u00f4le environnemental<\/li>\n<\/ul>\n<hr data-start=\"2783\" data-end=\"2786\" \/>\n<h2 data-section-id=\"6yw8gn\" data-start=\"2788\" data-end=\"2820\">Principaux Th\u00e8mes du Programme<\/h2>\n<h3 data-section-id=\"juh2t0\" data-start=\"2822\" data-end=\"2865\">1. Fondamentaux des Syst\u00e8mes \u00c9lectriques<\/h3>\n<ul data-start=\"2867\" data-end=\"3022\">\n<li data-section-id=\"17or97\" data-start=\"2867\" data-end=\"2922\">Architecture et composants des syst\u00e8mes \u00e9lectriques<\/li>\n<li data-section-id=\"12r27uv\" data-start=\"2923\" data-end=\"2972\">Machines synchrones et m\u00e9thodes de g\u00e9n\u00e9ration<\/li>\n<li data-section-id=\"14jy1b1\" data-start=\"2973\" data-end=\"3022\">Production thermique et production distribu\u00e9e<\/li>\n<\/ul>\n<hr data-start=\"3024\" data-end=\"3027\" \/>\n<h3 data-section-id=\"wm0537\" data-start=\"3029\" data-end=\"3074\">2. Transformateurs et R\u00e9seaux de Transport<\/h3>\n<ul data-start=\"3076\" data-end=\"3263\">\n<li data-section-id=\"p6207m\" data-start=\"3076\" data-end=\"3135\">Types de transformateurs et principes de fonctionnement<\/li>\n<li data-section-id=\"f6pewr\" data-start=\"3136\" data-end=\"3172\">Applications des transformateurs<\/li>\n<li data-section-id=\"sy6yep\" data-start=\"3173\" data-end=\"3263\">Lignes de transport :\n<ul data-start=\"3199\" data-end=\"3263\">\n<li data-section-id=\"53m7ya\" data-start=\"3199\" data-end=\"3212\">structures,<\/li>\n<li data-section-id=\"15gn71d\" data-start=\"3215\" data-end=\"3228\">composants,<\/li>\n<li data-section-id=\"1ovq6xj\" data-start=\"3231\" data-end=\"3263\">calculs de fl\u00e8che et tension<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<hr data-start=\"3265\" data-end=\"3268\" \/>\n<h3 data-section-id=\"ypyaq0\" data-start=\"3270\" data-end=\"3294\">3. Postes \u00c9lectriques<\/h3>\n<ul data-start=\"3296\" data-end=\"3411\">\n<li data-section-id=\"48dkd8\" data-start=\"3296\" data-end=\"3337\">Classification des postes \u00e9lectriques<\/li>\n<li data-section-id=\"1v2a2f7\" data-start=\"3338\" data-end=\"3357\">Mise \u00e0 la terre<\/li>\n<li data-section-id=\"fyhu2w\" data-start=\"3358\" data-end=\"3389\">Protection contre la foudre<\/li>\n<li data-section-id=\"11zotqd\" data-start=\"3390\" data-end=\"3411\">S\u00e9curit\u00e9 incendie<\/li>\n<\/ul>\n<hr data-start=\"3413\" data-end=\"3416\" \/>\n<h3 data-section-id=\"1e7chdk\" data-start=\"3418\" data-end=\"3475\">4. R\u00e9seaux de Distribution et Utilisation de l\u2019\u00c9nergie<\/h3>\n<ul data-start=\"3477\" data-end=\"3597\">\n<li data-section-id=\"5v8210\" data-start=\"3477\" data-end=\"3521\">Mod\u00e9lisation des r\u00e9seaux de distribution<\/li>\n<li data-section-id=\"19sqq8u\" data-start=\"3522\" data-end=\"3545\">Analyse des charges<\/li>\n<li data-section-id=\"1pegjmq\" data-start=\"3546\" data-end=\"3597\">Comptage \u00e9nerg\u00e9tique et profils de consommation<\/li>\n<\/ul>\n<hr data-start=\"3599\" data-end=\"3602\" \/>\n<h3 data-section-id=\"p83m7x\" data-start=\"3604\" data-end=\"3663\">5. Analyse Syst\u00e8me, Simulation et Diagnostic des D\u00e9fauts<\/h3>\n<ul data-start=\"3665\" data-end=\"3790\">\n<li data-section-id=\"1hmi1hd\" data-start=\"3665\" data-end=\"3705\">Mod\u00e9lisation des r\u00e9seaux \u00e9lectriques<\/li>\n<li data-section-id=\"1dfmson\" data-start=\"3706\" data-end=\"3740\">M\u00e9thodes d\u2019analyse des d\u00e9fauts<\/li>\n<li data-section-id=\"1sl48xc\" data-start=\"3741\" data-end=\"3790\">Outils de simulation des syst\u00e8mes \u00e9lectriques<\/li>\n<\/ul>\n<hr data-start=\"3792\" data-end=\"3795\" \/>\n<h3 data-section-id=\"1n70c2t\" data-start=\"3797\" data-end=\"3838\">6. Protection et R\u00e9ponses Transitoires<\/h3>\n<ul data-start=\"3840\" data-end=\"4000\">\n<li data-section-id=\"7pakp2\" data-start=\"3840\" data-end=\"3870\">Protection des g\u00e9n\u00e9rateurs<\/li>\n<li data-section-id=\"1b42r6g\" data-start=\"3871\" data-end=\"3907\">Techniques de relais \u00e9lectriques<\/li>\n<li data-section-id=\"b1ify0\" data-start=\"3908\" data-end=\"3968\">Surtensions dues \u00e0 la foudre et man\u0153uvres de commutation<\/li>\n<li data-section-id=\"xc9et3\" data-start=\"3969\" data-end=\"4000\">Coordination de l\u2019isolation<\/li>\n<\/ul>\n<hr data-start=\"4002\" data-end=\"4005\" \/>\n<h3 data-section-id=\"hd4nh8\" data-start=\"4007\" data-end=\"4047\">7. Stabilit\u00e9 et Dynamique des R\u00e9seaux<\/h3>\n<ul data-start=\"4049\" data-end=\"4208\">\n<li data-section-id=\"1m51htu\" data-start=\"4049\" data-end=\"4100\">Comportement dynamique des syst\u00e8mes \u00e9lectriques<\/li>\n<li data-section-id=\"1qsnxdb\" data-start=\"4101\" data-end=\"4169\">Types de stabilit\u00e9 :\n<ul data-start=\"4126\" data-end=\"4169\">\n<li data-section-id=\"72zr8y\" data-start=\"4126\" data-end=\"4140\">transitoire,<\/li>\n<li data-section-id=\"tvwqqb\" data-start=\"4143\" data-end=\"4155\">dynamique,<\/li>\n<li data-section-id=\"9disq4\" data-start=\"4158\" data-end=\"4169\">tension<\/li>\n<\/ul>\n<\/li>\n<li data-section-id=\"13lf0vq\" data-start=\"4170\" data-end=\"4208\">M\u00e9thodes d\u2019att\u00e9nuation et contr\u00f4le<\/li>\n<\/ul>\n<hr data-start=\"4210\" data-end=\"4213\" \/>\n<h3 data-section-id=\"1g9uzfl\" data-start=\"4215\" data-end=\"4269\">8. Planification, Fiabilit\u00e9 et S\u00e9curit\u00e9 des R\u00e9seaux<\/h3>\n<ul data-start=\"4271\" data-end=\"4397\">\n<li data-section-id=\"75oiy\" data-start=\"4271\" data-end=\"4311\">M\u00e9thodes de planification \u00e9lectrique<\/li>\n<li data-section-id=\"o58mex\" data-start=\"4312\" data-end=\"4336\">Analyse de fiabilit\u00e9<\/li>\n<li data-section-id=\"19e2xho\" data-start=\"4337\" data-end=\"4397\">S\u00e9curit\u00e9 des r\u00e9seaux et consid\u00e9rations environnementales<\/li>\n<\/ul>\n<hr data-start=\"4399\" data-end=\"4402\" \/>\n<h3 data-section-id=\"1qrg061\" data-start=\"4404\" data-end=\"4459\">9. \u00c9lectronique de Puissance et Qualit\u00e9 de l\u2019\u00c9nergie<\/h3>\n<ul data-start=\"4461\" data-end=\"4582\">\n<li data-section-id=\"3ojd9h\" data-start=\"4461\" data-end=\"4507\">Applications pour le contr\u00f4le des syst\u00e8mes<\/li>\n<li data-section-id=\"1llt98o\" data-start=\"4508\" data-end=\"4548\">Harmoniques et r\u00e9gulation de tension<\/li>\n<li data-section-id=\"4xwcv2\" data-start=\"4549\" data-end=\"4582\">Normes de qualit\u00e9 \u00e9nerg\u00e9tique<\/li>\n<\/ul>\n<hr data-start=\"4584\" data-end=\"4587\" \/>\n<h3 data-section-id=\"17db7oi\" data-start=\"4589\" data-end=\"4634\">10. Dispatching \u00c9conomique et Optimisation<\/h3>\n<ul data-start=\"4636\" data-end=\"4726\">\n<li data-section-id=\"1mhi5b7\" data-start=\"4636\" data-end=\"4684\">R\u00e9partition \u00e9conomique des unit\u00e9s thermiques<\/li>\n<li data-section-id=\"1cwp5sb\" data-start=\"4685\" data-end=\"4726\">M\u00e9thodes d\u2019optimisation et r\u00e9solution<\/li>\n<\/ul>\n<hr data-start=\"4728\" data-end=\"4731\" \/>\n<h3 data-section-id=\"11cjpxr\" data-start=\"4733\" data-end=\"4755\">Approche P\u00e9dagogique<\/h3>\n<p data-start=\"4757\" data-end=\"4780\">Le programme comprend :<\/p>\n<ul data-start=\"4782\" data-end=\"5036\">\n<li data-section-id=\"1twy6yn\" data-start=\"4782\" data-end=\"4825\">Cours anim\u00e9s par des experts du secteur<\/li>\n<li data-section-id=\"1kdfnhc\" data-start=\"4826\" data-end=\"4854\">Discussions interactives<\/li>\n<li data-section-id=\"1r86hm2\" data-start=\"4855\" data-end=\"4880\">\u00c9tudes de cas r\u00e9elles<\/li>\n<li data-section-id=\"ot7fqe\" data-start=\"4881\" data-end=\"4928\">Exercices pratiques de calcul et simulation<\/li>\n<li data-section-id=\"d2fpv6\" data-start=\"4929\" data-end=\"4976\">Analyse de sc\u00e9narios de d\u00e9fauts \u00e9lectriques<\/li>\n<li data-section-id=\"1urrbt4\" data-start=\"4977\" data-end=\"5036\">Supports techniques de r\u00e9f\u00e9rence pour approfondissement<\/li>\n<\/ul>\n<hr data-start=\"5038\" data-end=\"5041\" \/>\n<h3 data-section-id=\"pafvqr\" data-start=\"5043\" data-end=\"5059\">Contactez-nous<\/h3>\n<p data-start=\"5061\" data-end=\"5112\">Pour toute information compl\u00e9mentaire ou question :<\/p>\n<p data-start=\"5114\" data-end=\"5144\">\ud83d\udcf1 WhatsApp : +44 754 892 5284<\/p>\n<p data-start=\"5146\" data-end=\"5184\">Nous serons ravis de vous accompagner.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Syst\u00e8mes \u00c9lectriques et Centrales de Production (Conception, Installation et Maintenance) Programme : Syst\u00e8mes Modernes d\u2019\u00c9nergie \u00c9lectrique \u2013 Conception, Exploitation et Contr\u00f4le Pr\u00e9sentation du Programme L\u2019industrie de l\u2019\u00e9nergie \u00e9lectrique conna\u00eet aujourd\u2019hui une transformation rapide sous l\u2019effet : de la d\u00e9r\u00e9glementation, de &hellip; <\/p>\n","protected":false},"author":1,"featured_media":35043,"comment_status":"open","ping_status":"closed","template":"","course_category":[212],"course_tag":[252],"class_list":["post-35041","lp_course","type-lp_course","status-publish","has-post-thumbnail","hentry","course_category-genie-electrique-et-energetique","course_tag-londres","course"],"acf":[],"_links":{"self":[{"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/lp_course\/35041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/lp_course"}],"about":[{"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/types\/lp_course"}],"author":[{"embeddable":true,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/comments?post=35041"}],"version-history":[{"count":2,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/lp_course\/35041\/revisions"}],"predecessor-version":[{"id":36606,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/lp_course\/35041\/revisions\/36606"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/media\/35043"}],"wp:attachment":[{"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/media?parent=35041"}],"wp:term":[{"taxonomy":"course_category","embeddable":true,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/course_category?post=35041"},{"taxonomy":"course_tag","embeddable":true,"href":"https:\/\/oakbridgecollege.co.uk\/fr\/wp-json\/wp\/v2\/course_tag?post=35041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}